DEFINITY Enterprise Communications Server  Release 6
Maintenance for R6vs/si  
555-230-127   
Issue 1
August 1997
Maintenance Commands and Trouble-Clearing Aids 
Page 8-56
display disabled-tests 
8
display disabled-tests
The 
display disabled-tests
 command lists the numbers for all maintenance tests 
that have been disabled by INADS. These tests are not available for background 
or demand testing.
Output
The following example shows the output from the 
display disabled-tests
 
command.
1.
Refer to the Report Scheduler and System Printer feature specification for more details.
Remote Port
The application port used by the remote session.
Adjunct Name
The name of the adjunct connected to this processor channel. 
These are defined in the Adjunct Name Form. Only AUDIX and 
MSA channels require entries in this field: AUDIX, MSAAMWL, 
MSAHLWC, MSALLWC, and MSAMCS.
Machine-ID
The network machine ID for the remote machine. Machine IDs 
are required only for the AUDIX adjunct and DCS connections.
Action/Object
Qualifier
Qualifier Description
Permissions
Defaults
Feature
Interactions
display 
disabled-tests
print
schedule
Report sent to printer
Command is validated and then a 
scheduling form displays to 
schedule execution of the 
command. The command is then 
placed in the command queue 
and is executed at the specified 
time. The information displayed 
by the command is sent to the 
system printer instead of the 
screen.
1
init
inads
craft
cust
rcust
none
none
 
 display disabled-tests                                  SPE A
                          DISABLED TEST INFORMATION
 
          Test Number
 
          710
 
 
 Command successfully completed