Lucent Technologies lucent ユーザーズマニュアル

ページ / 2392
DEFINITY Enterprise Communications Server  Release 6
Maintenance for R6vs/si  
555-230-127   
Issue 1
August 1997
Maintenance Commands and Trouble-Clearing Aids 
Page 8-109
list measurements 
8
Output
Field descriptions
list measurements
This command lists performance measurements of a DS-1 link indicating the 
quality of the DS-1 physical interface between the system and a far end system. 
The 
ds1 summary
 option provides a summary report while the 
ds1 log
 option 
provides a detailed report.
1.
Refer to the Report Scheduler and System Printer feature specification for more details.
Action/Object
Qualifier
Qualifier Description
Permissions
Defaults
Feature
Interactions
list 
marked-ports
print
schedule
Report sent to printer.
Command is validated and then a 
scheduling form displays to 
schedule execution of the 
command. The command is then 
placed in the command queue and 
is executed at the specified time. 
The information displayed by the 
command is sent to the system 
printer instead of the screen.
1
Examples:
list marked-ports
list marked-ports print
list marked-ports schedule
init
inads
craft
cust
rcust
bcms
browse
none
none
Port
The port address (cabinet-carrier-slot-circuit) of the marked port.
Board-Type
The type of circuit pack containing the marked port. If this circuit pack 
information is no longer available because the circuit pack was 
removed after the port was marked, the 
Board-Type
 field is blank.
 
list marked-ports
             MARKED-PORT INFORMATION
     Port     Board-Type
     1C0101   DIG-BD
     1C0601
     1C0702   DIG-BD
 Command successfully completed