Lucent Technologies lucent ユーザーズマニュアル

ページ / 2392
DEFINITY Enterprise Communications Server  Release 6
Maintenance for R6vs/si  
555-230-127   
Issue 1
August 1997
Maintenance Commands and Trouble-Clearing Aids 
Page 8-111
list measurements 
8
Output
Field descriptions (list measurements 
ds1-summary)
Counted 
Since:
The start time and date when the associated measurement counters 
were cleared or the DS1 circuit pack was administered.
Number of 
Seconds 
Elapsed Into 
Current 
15-min 
Interval:
The number of seconds from the beginning of the current 15-minute 
interval (0 - 900).
Total of 
Valid 15-min 
Intervals in 
Past 24-hr 
Period:
The total number of 15-minute intervals in the past 24-hour period that 
contain valid data (0 - 96).
 
list measurements ds1 summary 2a19                     SPE A
 Switch Name:                  Date: 1:25 pm  THU APR 16, 1992
      DS-1 Link Performance Measurements Summary Report
   Counted Since: 1:20 pm  THU APR 16, 1992
   Number of Seconds Elapsed Into Current 15-min Interval: 323
   Total of Valid 15-min Intervals in Past 24-hr Period:   0
                                           Total of  Current
                  Worst_15-Min_Interval    24-hr     15-Min Interval
   Category         Date   Time   Count    Count     Count
 Errored Seconds    4/16   13:20     0      0         4
 Bursty Err Secs    4/16   13:20     0      0         4
 Severely Err Secs  4/16   13:20     0      0         0
 Failed Seconds     4/16   13:20     0      0         0
 Command successfully completed