Lucent Technologies lucent ユーザーズマニュアル

ページ / 2392
DEFINITY Enterprise Communications Server  Release 6
Maintenance for R6vs/si  
555-230-127   
Issue 1
August 1997
Maintenance Commands and Trouble-Clearing Aids 
Page 8-139
list mst 
8
Application Control
0xA2 - X.25 application error or notification
NOTE:
The ’X.25 application error message’ category contains notifications as well 
as errors.
0xA2, 0xF0 and 0xF2 messages will be turned on by responding ’y’ to the 
’Application Errors?’ field.
Version 1:
Version 2:
Errors/Notifications:
  R1/R3:
    0x01  - no outgoing buffer available
    0x05  - pvc session down
    0x06  - pvc session up
    0x07  - pvc session connect
    0x08  - pvc session restart
    0x09  - message buffer overload uplink
    0x0A  - message buffer overload downlink
    0x0B  - message buffer exhaustion
    0x0C  - max # of outgoing msgs allowed
    0x0D  - bad msg type in message buffer routine
    0x0E  - no message buffers available
    0x0F  - message buffer pointer error
    0x10  - pm state table stimulus ignored
    0x11  - bad session connect message
Session Layer Control
NOTE:
The session layer header is considered part of the session layer message.
Message[1]
= processor channel number
Message[2]
= application error/notification
Message[1]
= processor channel number
Message[2]
= application error/notification
Message[3+]
= pm stimulus ignored (For message[2] == 0x10 only)