status signaling-group 
8
status signaling-group
This command displays the state, type, port location, and state of the Primary 
and Secondary D-channels within the group. A signaling group is a collection of 
B-channels signaled for by a designated single D-channel or set of D-channels 
over an ISDN-PRI.
Output
The following output example shows the output from the 
status 
signaling-group 1
 command.
Channel Status
State the channel is in:
1. Channel is not administered.
2. Channel is administered but not used.
3. Channel is in a state entering “wait session accept” (WSA).
4. Channel is in a state waiting for a “session accept” message 
from the far end.
5. Channel is waiting for action.
6. Channel is in data transfer state (channel up and running).
7. Channel is in resynchronization state.
8. Channel is waiting for acknowledge of disconnect message.
9. ISDN-PRI Channel is currently down.
10. ISDN-PRI Channel is in the data transfer state (that is, channel 
is up and running).
Reset Count
Number of times reset has been issued for this channel
Message Buffer 
Number
Number of message buffers currently used for communication on 
this channel.
Link Number
Physical SCI link (i1-8) associated with the channel
Retransmission
Count
Number of times that message retransmission has occurred
Action/Object
Qualifier
Qualifier Description
Permissions
Defaults
Feature
Interactions
status 
signaling- 
group
group 
identifier
print
Administered group identifier 
number (1-8)
Report sent to printer
Examples:
status signaling-group 1
status signaling-group 2 print