DEFINITY Enterprise Communications Server  Release 6
Maintenance for R6vs/si  
555-230-127   
Issue 1
August 1997
Maintenance Commands and Trouble-Clearing Aids 
Page 8-296
status signaling-group 
8
Field descriptions
Group ID:
Numerical ID of the signaling group (1-8)
Type:
facility associated signaling
: all members are on a single 
DS-1 facility. Facility associated signaling groups support only the 
simplex D-channel configuration.
non-facility associated signaling
: members can be carried 
by multiple DS-1 facilities.
The DS-1 facility is identified across the ISDN-PRI using an explicit 
facility identifier. In a simplex configuration one D-channel is used to 
signal for B-channel members, while in a duplex configuration two 
D-channels are used to signal for B-channel members (one channel is 
active and the other is used as a backup to the active channel).
Group State:
in-service
: one of the D-channels signaling for the group is in 
service
out-of-service
: neither D-channel in the group is in service
NOTE:
If there is no D-channel backup and the primary D-channel is 
out-of-service, then the signaling group is in an out-of-service 
state.
Link:
Link transporting the D-channel
Port:
Address of the port transporting either the primary or secondary 
D-channel
 
 status signaling-group 1                   Page 1 of   1   SPE A
                      STATUS SIGNALING-GROUP
       Group ID: 1
           Type: facility associated signaling
    Group State: in-service
                      Primary D-Channel
  Link: 1    Port: 01C1924  Level 3 State: in-service
                     Secondary D-Channel
  Link:    Port:      Level 3 State: