Lucent Technologies lucent ユーザーズマニュアル

ページ / 2392
DEFINITY Enterprise Communications Server  Release 6
Maintenance for R6vs/si  
555-230-127   
Issue 1
August 1997
Maintenance Commands and Trouble-Clearing Aids 
Page 8-301
status system 
8
Output
The following example shows the output for the 
status synchronization
 
command.
Field descriptions
status system
This command displays the status, mode, and operational attributes of the 
SPE(s), TDM and Packet busses, tone-clock circuit pack(s), expansion interface 
links (exp-links), and emergency transfer switch of single or all cabinets in the 
system.
!
CAUTION:
The purpose of this command is to provide general information about the 
cabinet status. This information may not display correctly when the cabinet 
is in a transient period. In this case, wait for 1 minute and enter the 
command again.
Stratum Level
Synchronization stratum level (3 or 4)
Maintenance 
Name:
Either 
TONE-BD
DS1-BD
, or 
STRAT-3
.
Physical 
Location
Board location of the selected DS1 or tone-clock circuit pack 
(cabinet-carrier-slot for a DS1; cabinet-carrier for a tone-clock)
Switching 
Capability
Whether the on-line reference for synchronization can be switched 
(
Enabled
 or 
Disabled
)
Excessive 
Reference 
Switching
High-level description of how many times the synchronization 
reference has been switched. If excessive reference switching is 
taking place (sync error 1793 is at threshold), this field displays 
Yes
; otherwise 
No
 displays.
 
 status synchronization
                          SYNCHRONIZATION STATUS
                 Stratum Level:4
              Maintenance Name: TONE-BD   Physical Location: 01A
          Switching Capability: Enabled
 Excessive Reference Switching: No