Lucent Technologies lucent ユーザーズマニュアル
DEFINITY Enterprise Communications Server Release 6
Maintenance for R6vs/si
Maintenance for R6vs/si
555-230-127
Issue 1
August 1997
Maintenance Commands and Trouble-Clearing Aids
Page 8-300
status synchronization
8
status synchronization
This command displays the location of the DS1 or tone-clock circuit pack that is
used for an on-line synchronization reference. The synchronization subsystem
provides error free digital communication between the switch and other PBXs,
COs, or customer premise equipment. The subsystem is made up of: TDM bus
clock, DS1 trunk board, maintenance and administration software resident in the
SPE.
used for an on-line synchronization reference. The synchronization subsystem
provides error free digital communication between the switch and other PBXs,
COs, or customer premise equipment. The subsystem is made up of: TDM bus
clock, DS1 trunk board, maintenance and administration software resident in the
SPE.
Service State
In service/on-hook, in service/off-hook, out of service, or
disconnected.
disconnected.
Maintenance
Busy State
Whether maintenance is testing the object (
yes
or
no
)
SAC Activated
Whether send all calls is activated (
yes
or
no
)
User Cntrl
Restr
One or two of the following:
none
,
total
,
stat-stat
,
outward
or
terminate
.
Group Cntrl
Restr
One or two of the following:
none
,
total
,
stat-stat
,
outward
or
terminate
.
AWU Call at
Time that Automatic Wakeup Call is scheduled
User DND
Status of the do not disturb feature.
Group DND
Status of the group do not disturb feature.
Room Status
Whether a room is occupied or not (
non-guest room
,
vacant
, or
occupied
).
Action/Object
Qualifier
Qualifier Description
Permissions
Defaults
Feature
Interactions
Interactions
status
synchronization
synchronization
print
Report sent to printer
Examples:
status synchronization
status synchronization print
status synchronization print
init
inads
craft
cust
browse
inads
craft
cust
browse
none
none