Lucent Technologies lucent ユーザーズマニュアル

ページ / 2392
DEFINITY Enterprise Communications Server  Release 6
Maintenance for R6vs/si  
555-230-127   
Issue 1
August 1997
Maintenance Commands and Trouble-Clearing Aids 
Page 8-320
test alarms 
8
Field descriptions (Hardware Test Alarm Query)
Output
The following example shows the output from the 
test alarms
 command (query 
form left empty by pressing 
ENTER
). The responses display on a test-by-test basis 
with one line of data for each test result.
Alarm Types
The type of alarm to be tested: put 
y
 or 
n
 in the field(s) to selects one 
or a combination of alarms.
Interval
Tests alarms for the last hour (
h
), last day (
d
), last week (
w
) or all (
a
[default].
From
Test alarm from the specified time specified (
mm
/
dd
/
hh
/
mm
). If no 
from
 date is entered, then no checking is done and the alarms active 
since a month prior to the current time are reported.
To
Test alarms associated with records to the specified time specified 
(
mm
/
dd
/
hh
/
mm
). If no 
to
 date is entered, any alarm active after the 
from
 date is selected.
Equipment 
Type
The technician can choose between five different equipment types. If 
there is no input to any of these fields, the system defaults to all the 
equipment. The user can select one of the following fields:
Cabinet
: tests alarms associated with a particular cabinet (1-3). 
Port Network
: tests all alarms associated with a particular port 
network (1-3).
Board Number
: tests all alarms associated with a particular 
circuit pack (
PCss
, default cabinet = 1).
Port
: tests all alarms associated with a particular port on a 
circuit pack (
PCsspp
, default cabinet = 1).
Category
: Alarms for a particular equipment category
Extension
: Alarms associated with an extension number
Trunk
 (group/member): tests all alarms associated with a 
particular trunk group or trunk group member, 
XX
/
YY
, where the 
group identifier tests all alarms associated with a trunk group 
(
XX
/__), and the group identifier 
and
 member identifier are both 
entered to test all alarms associated with a specific trunk group 
member (
XX
/
YY
).