Maintenance Commands and Trouble-Clearing Aids 
Page 8-322
test analog-testcall 
8
test analog-testcall
The test analog-testcall command performs facility diagnostic tests on an entire 
trunk group, an individual trunk group member, an individual trunk port or on all 
trunks on a board, depending on the options entered. The type of test call, the 
far-end test line number, and the various other parameters must be administered 
on the trunk group form before executing the command. Normally, the user 
should only invoke the full or supervision test. The other options are provided 
primarily for testing when setting up an ATMS schedule.
Test results section
Port
Port address (cabinet-carrier-slot-circuit)
Maintenance 
Name
The name of maintenance object
Alt. Name
Alternate way to identify maintenance objects.
If the Object is
The field contains
station
extension
trunk
xxx/yyy
 (where 
xxx
 = trunk group number
and 
yyy
 = member number)
private CO line
P/xxx
 (where 
xxx
 = private CO line group 
number)
Test No
The test being executed
Result
Test result: Fail, Pass, Abort, or No Board. If this field has conflict, 
another user may be testing this hardware. If this field has 
epn-down
, the epn is inaccessible at this time.
Error Code
Numeric code explaining why the release failed or aborted. Refer 
to the detailed list of the codes by test number for each MO.