Lucent Technologies lucent ユーザーズマニュアル

ページ / 2392
DEFINITY Enterprise Communications Server  Release 6
Maintenance for R6vs/si  
555-230-127   
Issue 1
August 1997
Maintenance Commands and Trouble-Clearing Aids 
Page 8-332
test cdr-link 
8
Field descriptions
Port
Not applicable (always blank)
Maintenance
Name
The type of MO being tested: primary cdr-link= PRI-CDR; secondary 
cdr-link = SEC-CDR
Alt. Name
Not applicable (always blank)
Test No
The test being executed
Result
Test result: Pass, Abort, Fail, Disabled
Error Code
Numeric code explaining why the release failed or aborted. Refer to the 
detailed list of the codes by test number for each MO.
 
 test cdr-link primary short
                          TEST RESULTS
           
   Port    Maintenance Name  Alt. Name Test No. Result       Error Code
           PRI-CDR                     215      PASS
 Command Successfully Completed