Lucent Technologies lucent ユーザーズマニュアル

ページ / 2392
DEFINITY Enterprise Communications Server  Release 6
Maintenance for R6vs/si  
555-230-127   
Issue 1
August 1997
Maintenance Commands and Trouble-Clearing Aids 
Page 8-334
test data-module 
8
Defaults
The default cabinet is cabinet 1. The default carrier is carrier “a,” except for SPE 
duplex system PPNs. In this case the carrier has no default and either “a” or “b” 
must be entered. The default for the remaining parameter is a repeat of 1.
Output
The following example shows the output from the 
test customer-alarm 02a
 
command.
Field Definitions
test data-module
This command performs hardware diagnostic tests on a data module or data 
channel. Test results are determined by the interface to the digital switch-data 
line port, digital line port, or network control data channel.
Port
The port address (cabinet-carrier-slot)
Maintenance 
Name
The maintenance name (always CUST-ALM)
Alt. Name
Not applicable
Test No.
The test number (always 115)
Result
Test result: Pass, Abort, or Fail
Error Code
Numeric code explaining why the release failed or aborted. Refer 
to the detailed list of the codes by test number for each MO.
 
 test customer-alarm 02A
                                TEST RESULTS
   Port    Maintenance Name  Alt. Name Test No. Result       Error Code
   02A     CUST-ALM                    115      PASS
 Command Successfully Completed