Lucent Technologies lucent ユーザーズマニュアル

ページ / 2392
DEFINITY Enterprise Communications Server  Release 6
Maintenance for R6vs/si  
555-230-127   
Issue 1
August 1997
Maintenance Commands and Trouble-Clearing Aids 
Page 8-336
test ds1-loop 
8
Output
The following example shows the output from the 
test data-module 300
 
command. The responses display on a test-by-test basis with one line of data for 
each test result.
Field Definitions
test ds1-loop
This command validates that the board exists at the specified location and that 
the board is a TN464F or TN767E or later suffix DS1 Interface board. 
Long-duration loopback tests execute for an extended period of time until 
manually terminated. Short-duration loopback tests return the result of the test to 
the screen after executing. The 
list measurements ds1 summary
 command 
can be used to monitor the status of a long-duration loopback/span test.
Port
Port address (cabinet-carrier-slot-circuit)
Maintenance 
Name
The name of maintenance object
Alt. Name
Alternate way to identify maintenance objects.
If the Object is
The field contains
station
extension
trunk
xxx/yyy
 (where 
xxx
 = trunk group number
and 
yyy
 = member number)
private CO line
P/xxx
 (where 
xxx
 = private CO line group 
number)
Test No
The test being executed
Result
Test result: Pass, Fail, Abort, No Board
Error Code
Numeric code explaining why the release failed or aborted. Refer 
to the detailed list of the codes by test number for each MO.
 
 test data-module 300
                               TEST RESULTS
   Port      Maintenance Name  Alt. Name Test No. Result       Error Code
   01C1103   PDMODULE                      17     PASS
 Command successfully completed