Lucent Technologies lucent ユーザーズマニュアル

ページ / 2392
DEFINITY Enterprise Communications Server  Release 6
Maintenance for R6vs/si  
555-230-127   
Issue 1
August 1997
Maintenance Commands and Trouble-Clearing Aids 
Page 8-373
test pkt 
8
Feature Interactions
The reset packet-control test (#586) does not run on the active packet-control. 
This test is part of the standby packet-control test sequence, illustrated in the 
screen output section below.
Output
The following example is the screen output for the 
test packet-control 1B long
 
command. Note that carrier B is the active carrier in this example.
Field descriptions
test pkt
The test pkt runs a series of tests on the Packet bus of the specified PPN or EPN.
Port
Port address (cabinet-carrier-slot-circuit)
Maintenance 
Name
The name of maintenance object.
Alt. Name
Not applicable
Test No.
The test number run on the packet-control.
Result
Test result: Pass, Abort, Fail, No Board, Disabled, Extra Bd.
Error Code
Numeric code explaining why the release failed or aborted. Refer 
to the detailed list of the codes by test number for each MO.
 
 test packet-control 1B l
 
                               TEST RESULTS
 
  Port    Maintenance Name  Alt. Name Test No.  Result      Error Code
 
  01B     PKT-CTRL                     583      PASS
  01B     PKT-CTRL                     584      PASS
  01B     PKT-CTRL                     585      PASS
 Command successfully completed