Maintenance Commands and Trouble-Clearing Aids 
Page 8-400
test trunk 
8
Output
The responses display on a test-by-test basis with one line of data for each test 
result. The following screen is an example of the output for the 
test trunk 78
 
command.
1.
If no alarms are registered against the maintenance object then the test sequence exercises once. The
 long clear
 
option forces a clear of all alarms if no errors are encountered during testing. The 
short clear
 option only clears alarms 
pertinent to tests in the short sequence.
2.
Refer to the Report Scheduler and System Printer feature specification for more details.
Action/ 
Object
Qualifier
Qualifier Description
Permissions
Defaults
Feature
Interactions
test trunk
group 
number
member 
number
short
long
repeat 
number
clear
schedule
Administered group number (1-99)
Administered number identifying a 
particular trunk within a trunk group (1-99).
Command executes a series of 
nondestructive diagnostic tests.
Command executes a more 
comprehensive and longer version of the 
both destructive and nondestructive 
diagnostic tests.
How many times each test in the sequence 
is repeated (1-100)
This option causes the test sequence (short 
or long) to repeat until the alarm (if any) is 
cleared or a single test in the sequence 
fails.
1
Command is validated and then a 
scheduling form displays to schedule 
execution of the command. The command 
is then placed in the command queue and 
is executed at the specified time. The 
information displayed by the command is 
sent to the system printer instead of the 
screen.
2
Examples:
test trunk 78 l 
test trunk 80/1 sh r 2
test trunk 78/2 l r 25
test trunk 78/2 l r 25 schedule
test trunk 80
test trunk 80 schedule
test trunk 78 r 4
test trunk 78 c
init
inads
craft
cust
Test Seq. 
= short; 
Repeat = 1
none