Lucent Technologies lucent ユーザーズマニュアル

ページ / 2392
DEFINITY Enterprise Communications Server  Release 6
Maintenance for R6vs/si  
555-230-127   
Issue 1
August 1997
Maintenance Commands and Trouble-Clearing Aids 
Page 8-401
test tsc-administered 
8
Field descriptions
test tsc-administered
This command submits a switched services request to run the Temporary 
Signaling Connection’s heartbeat test for all administered TSCs on a signaling 
group.
Port
The port address: cabinet-carrier-slot-circuit
Maintenance 
Name
The name of maintenance object being tested.
Alt. Name
The alternate means of identifying the maintenance object. If the 
object is a trunk, the field contains 
xxx/yyy
 (where 
xxx
 = trunk 
group number, 
yyy
 = member number). If the object is a private 
CO line, the field contains 
P/xxx
 (where 
xxx
 = private CO line 
group number).
Test No
The test number being executed
Result
The result of the individual test: PASS, ABORT, FAIL, NO BOARD, 
DISABLED, and EXTRA BD.
Error Code
A system-generated number indicating the reason that the test for 
the named MO failed or aborted.
 
 test trunk 78
                             TEST RESULTS
 
   Port      Maintenance Name  Alt. Name Test No. Result       Error Code
   01C1505   CO-TRK            078/001   3        PASS
   01C1505   CO-TRK            078/001   36       PASS
 Command Successfully Completed