test tsc-administered
8
Field descriptions
test tsc-administered
This command submits a switched services request to run the Temporary
Signaling Connection’s heartbeat test for all administered TSCs on a signaling
group.
Signaling Connection’s heartbeat test for all administered TSCs on a signaling
group.
Port
The port address: cabinet-carrier-slot-circuit
Maintenance
Name
The name of maintenance object being tested.
Alt. Name
The alternate means of identifying the maintenance object. If the
object is a trunk, the field contains
object is a trunk, the field contains
xxx/yyy
(where
xxx
= trunk
group number,
yyy
= member number). If the object is a private
CO line, the field contains
P/xxx
(where
xxx
= private CO line
group number).
Test No
The test number being executed
Result
The result of the individual test: PASS, ABORT, FAIL, NO BOARD,
DISABLED, and EXTRA BD.
DISABLED, and EXTRA BD.
Error Code
A system-generated number indicating the reason that the test for
the named MO failed or aborted.
the named MO failed or aborted.
test trunk 78
TEST RESULTS
Port Maintenance Name Alt. Name Test No. Result Error Code
01C1505 CO-TRK 078/001 3 PASS
01C1505 CO-TRK 078/001 36 PASS
Port Maintenance Name Alt. Name Test No. Result Error Code
01C1505 CO-TRK 078/001 3 PASS
01C1505 CO-TRK 078/001 36 PASS
Command Successfully Completed