Packet Bus Fault Isolation and Correction 
Page 9-26
Packet Bus Fault Correction 
9
!
CAUTION:
Since Packet Bus fault isolation procedures involve removing circuit packs 
and possibly disconnecting entire carriers, these procedure have a 
profound effect on service. Therefore, if possible, implement these 
procedures after hours or during hours of minimum system use.
NOTE:
Each of these procedures contains one or more steps that require a 
determination as to whether the Packet Bus problem has been resolved. 
Accordingly, several condition checks must be performed. We can present 
each such check in the form of a question, as follows:
Did the Maintenance/Test circuit pack standalone mode initially indicate 
the existence of faulty leads, and are these leads no longer indicated?
Have all alarms against the Packet Bus and Packet circuit packs been 
resolved?
NOTE:
If all alarms are resolved, issue the 
clear pkt
 command. This 
command attempts to put the switch back into the service state by 
resolving any BRI problems that exist. Refer to 
, for more 
information.
Are all ISDN-BRI stations and data modules as well as any relevant ASAI 
adjuncts in service?
Note that if one of these conditions is not yet met, the others need not be 
checked.
The following sections discuss the four procedures for correcting Packet Bus 
faults.
Procedure 1
Procedure 1 determines if any circuit packs that use the Packet Bus have faults. 
For each circuit pack type (see 
), perform the following steps:
NOTE:
The circuit packs need not be checked in the order presented
 if the 
flowchart in this chapter has been followed
. However, if newly added circuit 
packs are involved, check these packs first, inasmuch as the packs are 
most likely to have caused a problem.
1. Display the Error and Alarm Logs for the circuit pack via the 
display 
errors
 and 
display alarms
 commands.