Lucent Technologies lucent ユーザーズマニュアル

ページ / 2392
DEFINITY Enterprise Communications Server  Release 6
Maintenance for R6vs/si  
555-230-127   
Issue 1
August 1997
Maintenance Object Repair Procedures 
Page 10-32
ADX16D-P (16-Port AUDIX Digital Port) 
10
Station (Digital) Audits Test (#17)
Digital Terminal Remote Loop Around Test (1201)
NPE Crosstalk Test (#9)
This test verifies that this port’s NPE channel talks on the selected time slot and 
that it never crosses over to time slots reserved for other connections. If the NPE 
is not working correctly, one-way and noisy connections may be observed. This 
test is part of a port’s Long Test Sequence, and it takes about 20 to 30 seconds 
to complete. 
Crosstalk testing is performed on both the primary information channel (voice) 
and on the secondary information channel (data) associated with each DEFINITY 
AUDIX port. If this test fails on either channel, the voice port is taken 
out-of-service.
Table 10-13.
TEST #9 NPE Crosstalk Test 
Error 
Code
Test 
Result
Description/Recommendation
1
ABORT
During testing of the primary information channel, system resources may 
not have been available. Also, the port may have been busy during the 
test.
1. Check the port status. Use the 
display port PCSSpp
 command to 
determine the voice port extension of the port. Use the 
status station
 
command to determine the service state of the port. If the port is in 
use, it is unavailable for this test. Wait until the port is idle (a).
2
ABORT
System resources may not have been available, or the port may have been 
busy during the test.
1. Check if port is being used try (a)
1000
ABORT
System resources required to run this test are not available. The port may 
be in use. Use the 
display port PCSSpp
 command to determine the voice 
port extension of the port. Use the 
status station
 command to determine 
the service state of the port. If the port is in use, it is unavailable for certain 
tests. Refer to “Status” commands in Chapter 8, "Maintenance Commands 
and Trouble-Clearing Aids", for a full description of all possible states. Wait 
until the port is idle before testing.
1. If the port status is idle, try (a)
1001
ABORT
System resources required to run this test are not available. Try (a)
1002
ABORT
The system could not allocate time slots for the test. The system may be 
under heavy traffic conditions, or it may have time slots out-of-service due 
to TDM-BUS errors. Refer to “TDM-BUS” to diagnose TDM-BUS errors.
1. If system has no TDM-BUS errors, and if it is not handling heavy traffic, 
try (a)
Continued on next page