Lucent Technologies lucent ユーザーズマニュアル
DEFINITY Enterprise Communications Server Release 6
Maintenance for R6vs/si
Maintenance for R6vs/si
555-230-127
Issue 1
August 1997
Maintenance Object Repair Procedures
Page 10-33
ADX16D-P (16-Port AUDIX Digital Port)
10
Note:
a. Retry the command at 1-minute intervals a maximum of 5 times.
Voice and Control Channel Local Loop Test (#13)
This test checks the information and control channels between the Switch
Processing Element (SPE) and the DEFINITY AUDIX port circuit. The SPE sends
a message to loop around both the information and control channels for the port.
First, the primary information (voice) channel loop back test is run.
Processing Element (SPE) and the DEFINITY AUDIX port circuit. The SPE sends
a message to loop around both the information and control channels for the port.
First, the primary information (voice) channel loop back test is run.
While the primary information channel is still looped around, the Control Channel
Loop Around Test is performed. The Loop Around Test for the secondary
Loop Around Test is performed. The Loop Around Test for the secondary
1003
ABORT
The system could not allocate a tone receiver for the test. The system may
be oversized for the number of tone detectors present, or some tone
detectors may be out-of-service.
be oversized for the number of tone detectors present, or some tone
detectors may be out-of-service.
1. Resolve any “TTR-LEV” errors in the Error Log.
2. Resolve any “TONE-PT” errors in the Error Log.
1004
ABORT
The port was put in use during the test. The test has been aborted. Use the
display port PCSSpp
command to determine the voice port extension of
the port. Use the
status station
command to determine the service state of
the port. If the port is in use, it is unavailable for certain tests. Refer to
“Status” commands in Chapter 8 for explanations of all possible states.
Wait until the port is idle before testing.
“Status” commands in Chapter 8 for explanations of all possible states.
Wait until the port is idle before testing.
1020
ABORT
Test disabled via background testing. Use the
status station
command to
determine when the voice port is available for testing.
2000
ABORT
Response to the test request was not received within the allowable time
period (a).
period (a).
1
2
2
FAIL
The NPE of the tested port was found to be transmitting in error. This
causes noisy and unreliable connections. Failure code 1 indicates that the
Crosstalk test failed on the primary channel. Failure code 2 indicates that
the Crosstalk test failed on the secondary channel.
causes noisy and unreliable connections. Failure code 1 indicates that the
Crosstalk test failed on the primary channel. Failure code 2 indicates that
the Crosstalk test failed on the secondary channel.
1. Replace the circuit pack (see caution at the beginning of this section).
PASS
The port is using its allocated time slots correctly.
1. To be sure that this is not an intermittent problem, repeat this test up to
a maximum of 10 times to make sure it continues to pass.
2. If complaints still exist, examine the connections.
Table 10-13.
TEST #9 NPE Crosstalk Test —
Continued
Error
Code
Code
Test
Result
Description/Recommendation
Continued on next page