Maintenance Object Repair Procedures 
Page 10-33
ADX16D-P (16-Port AUDIX Digital Port) 
10
Note:
a. Retry the command at 1-minute intervals a maximum of 5 times.
Voice and Control Channel Local Loop Test (#13)
This test checks the information and control channels between the Switch 
Processing Element (SPE) and the DEFINITY AUDIX port circuit. The SPE sends 
a message to loop around both the information and control channels for the port. 
First, the primary information (voice) channel loop back test is run. 
While the primary information channel is still looped around, the Control Channel 
Loop Around Test is performed. The Loop Around Test for the secondary 
1003
ABORT
The system could not allocate a tone receiver for the test. The system may 
be oversized for the number of tone detectors present, or some tone 
detectors may be out-of-service.
1. Resolve any “TTR-LEV” errors in the Error Log.
2. Resolve any “TONE-PT” errors in the Error Log.
1004
ABORT
The port was put in use during the test. The test has been aborted. Use the 
display port PCSSpp
 command to determine the voice port extension of 
the port. Use the 
status station
 command to determine the service state of 
the port. If the port is in use, it is unavailable for certain tests. Refer to 
“Status” commands in Chapter 8 for explanations of all possible states. 
Wait until the port is idle before testing.
1020
ABORT
Test disabled via background testing. Use the 
status station
 command to 
determine when the voice port is available for testing.
2000
ABORT
Response to the test request was not received within the allowable time 
period (a).

FAIL
The NPE of the tested port was found to be transmitting in error. This 
causes noisy and unreliable connections. Failure code 1 indicates that the 
Crosstalk test failed on the primary channel. Failure code 2 indicates that 
the Crosstalk test failed on the secondary channel.
1. Replace the circuit pack (see caution at the beginning of this section).
PASS
The port is using its allocated time slots correctly.
1. To be sure that this is not an intermittent problem, repeat this test up to 
a maximum of 10 times to make sure it continues to pass.
2. If complaints still exist, examine the connections.
Table 10-13.
TEST #9 NPE Crosstalk Test  — 
Continued
Error 
Code
Test 
Result
Description/Recommendation
Continued on next page