Lucent Technologies lucent ユーザーズマニュアル

ページ / 2392
DEFINITY Enterprise Communications Server  Release 6
Maintenance for R6vs/si  
555-230-127   
Issue 1
August 1997
Maintenance Object Repair Procedures 
Page 10-191
BRI-SET, ASAI-ADJ, BRI-DAT 
10
System Technician-Demanded Tests: 
Descriptions and Error Codes
When inspecting errors in the system and deciding which ones to address, 
always investigate errors associated with the circuit pack and port first. Clearing 
these error codes first may also clear errors generated against the endpoint. 
When all circuit pack and port errors have been cleared, and errors still exist 
against the endpoint, always investigate errors in the order they are presented in 
the table below. By clearing error codes associated with the 
Signaling Link 
Status Test,
 for example, you may also clear errors generated from other tests in 
the testing sequence.
65
Bearer Service 
Not Implemented
Requested service not implemented in switch or 
endpoint.
69
Requested 
Facility Not 
Implemented
Requested service not supported in switch or 
endpoint.
1. Consult switch and endpoint documentation to 
determine service support.
2. If Step 1 does not resolve the problem, escalate 
to the next tier.
ADJUNCT/SWITCH ERROR CONDITIONS
81
Invalid CRV
An invalid CRV was sent by the adjunct.
1. This may indicate a CRV inconsistency between 
the switch and the adjunct. See the CallVisor 
protocol reference manual.
2. If step 1 does not resolve the problem, escalate 
to the next tier.
Table 10-68.
System Technician-Demanded Tests: BRI-SET
Order of Investigation
Short Test 
Sequence
Long Test 
Sequence
D/ND
1
Signaling Link Status Test (#626)
X
X
ND
BRI XID Test (#628)
X
X
ND
BRI Layer 3 Query (#629)
X (a)
X (a)
ND
Continued on next page
Table 10-67.
ISDN-BRI Cause Values  — 
Continued
Code
Explanation
Recommendation
Continued on next page