Maintenance Object Repair Procedures 
Page 10-323
CO-TRK (CO Trunk) 
10
Transmission Test (#844-848)
This test is non-destructive.
NOTE:
Tests #844-848 are not supported on a International switch.
These tests are run by the Automatic Transmission Measurement System 
(ATMS). They are not part of the long or short trunk test sequences. Instead, they 
are run on demand with the 
test analog-testcall
 command or as part of ATMS 
scheduled testing.
The test call is run from an analog port on a TN771 Maintenance/Test circuit 
pack. It attempts to seize a port and make a call to a terminating test line (TTL) on 
the trunk’s far end. Transmission performance measurements are made and 
compared to administered thresholds. Errors are generated when results fall 
outside of ‘‘marginal’’ or ‘‘unacceptable’’ thresholds. Detail and summary 
measurement reports are obtainable via the 
list testcalls
 command.
Table 10-106.
TEST #844-848 Transmission Test 
Error 
Code
Test 
Result
Description/ Recommendation
1000
ABORT
System resources required to run this test are not available. The port may 
be busy with a valid call. Use 
display port PCSSpp
 to determine the trunk 
group/member number of the port. Use the "status trunk" command to 
determine the service state of the port. If the service state indicates that the 
port is in use, then the port unavailable for this test. (Refer to the "Status 
Commands" section in Chapter 10, "Maintenance Commands and 
Trouble-Clearing Aids" for a full description all possible states). You must 
wait until the port is idle before retesting.
1. If the port status is idle, then retry the command at 1 minute intervals 
for a maximum of 5 retries.
2. If the test continues to abort escalate the problem.
1001
ABORT
Could not allocate the necessary system resources to run this test. 
1. Retry the command at 1 minute intervals for a maximum of 5 retries.
2. If the test continues to abort escalate the problem.
1002
ABORT
The system could not allocate timeslots for the test. The system may be 
under heavy traffic conditions or it may have timeslots out of service due to 
TDM bus errors. Refer to TDM Bus Maintenance to diagnose any active 
TDM bus errors. 
1. If system has no TDM bus errors and is not handling heavy traffic, 
repeat test at 1 minute intervals for a maximum of 5 retries. 
2. If the test continues to abort escalate the problem.
Continued on next page