Patton electronic 29XX ユーザーズマニュアル

ページ / 326
Configuring Frame Relay
319
Access Server Administrators’ Reference Guide 
C • Technical Reference
Configuring Frame Relay link parameters
Click on 
Frame Relay
 under the 
Configuration Menu
 to display the 
Frame Relay
 main window (see 
Click on 
Modify
 to display the DLMI window.  
Figure 129. DLMI window
Each Frame Relay instance with the access server is known as the data link management interface or DLMI. The 
access server software currently supports one Frame Relay Link, or DLMI, on each of the T1/E1 WAN ports. 
Frame Relay has a set of protocols responsible for maintaining the link. This is known as the management link 
interface
 or LMI. The management protocol link must agree with your service provider. In most cases, the sig-
naling setting may be the only variable you will need to change. 
The common link management, or signaling, protocols are:
LMI. Frame Relay Forum Implementation agreement. Uses DLCI = 1023 for management 
Annex D. ANSI T1.617 Uses DLCI = 0 for management
Annex A. ITU Q.933 Uses DLCI = 0 for management
Do the following to change the signaling method:
1. Click on the 
Signaling
 drop-down menu and select 
ansiT1-617-D(3)
.
2. Click 
Submit
.
Configuring PVCs
The Frame Relay link is now configured and should be available. The final stage will be to configure PVCs and 
IP routing so traffic can be routed to the new link(s).