Motorola MS4407 ユーザーズマニュアル
4 - 8
Symbol MS4404/MS4407 Integration Guide
Symbol MS4407 Imager Technical Specifications
Table 4-4
Symbol MS4407 Technical Specifications at 23° C
Item
Description
Power Requirements
Input Voltage
Input Current
Input Current
4.5 V (min) to 5.5 V (max)
5 V in presentation mode active scan with external illumination;
245 mA (max)
5 V in presentation mode active scan with external illumination;
245 mA (max)
Aiming Element
Visible Laser Diode (VLD)
VLD Power
Pattern Angle
Aiming Error
VLD Power
Pattern Angle
Aiming Error
650 nm ± 5 nm
0.7 mW Maximum
30.0º horizontal, 22.5º vertical
Total aiming error is 6.0 mm offset (horizontal)
Maximum angular aiming error is 1.5º
0.7 mW Maximum
30.0º horizontal, 22.5º vertical
Total aiming error is 6.0 mm offset (horizontal)
Maximum angular aiming error is 1.5º
Field of View
Horizontal
Vertical
Vertical
33.2 degrees
24.5 degrees
24.5 degrees
Focal Distance from Front of Engine
Near Focus
Far Focus
Far Focus
5 inches
9 inches
9 inches
Illumination Element
Light Emitting Diode (LED)
635 nm ± 20 nm (Internal/External)
Image File Formats
BMP, TIFF, JPEG
Interface
0 - 5 V Serial (TTL 232), USB1.1
Optical Resolution (gray scale)
640 (H) x 480 (V) pixels
Pitch Angle
Roll
360º (see
Skew Tolerance
Note: Environmental and/or tolerance parameters are not cumulative. A thermal analysis
is recommended if the application is subject to an extreme temperature environment.
is recommended if the application is subject to an extreme temperature environment.