Symbol MS4407 Imager Technical Specifications
Table 4-4    
Symbol MS4407 Technical Specifications at 23° C
Item
Description
Power Requirements
Input Voltage 
Input Current
4.5 V (min) to 5.5 V (max)
5 V in presentation mode active scan with external illumination;
245 mA (max) 
Aiming Element 
Visible Laser Diode (VLD)
VLD Power
Pattern Angle
Aiming Error
650 nm ± 5 nm 
0.7 mW Maximum 
30.0º horizontal, 22.5º vertical 
Total aiming error is 6.0 mm offset (horizontal) 
Maximum angular aiming error is 1.5º 
Field of View
Horizontal
Vertical
33.2 degrees
24.5 degrees
Focal Distance from Front of Engine
Near Focus 
Far Focus
5 inches 
9 inches
Illumination Element
Light Emitting Diode (LED)
635 nm ± 20 nm (Internal/External)
Image File Formats
BMP, TIFF, JPEG
Interface
0 - 5 V Serial (TTL 232), USB1.1
Optical Resolution (gray scale)
640 (H) x 480 (V) pixels 
Pitch Angle
± 60º from normal (see 
Roll
360º (see 
Skew Tolerance
± 50º from normal (see 
Note: Environmental and/or tolerance parameters are not cumulative. A thermal analysis 