Canon GM-1000 ユーザーズマニュアル
CANON Digital Galvano Scanner System GM-1000 Series
Users Manual 1.20
Users Manual 1.20
122
Parameter ID
45
Parameter
Name
Loop Gain Fine Adjustment
Data
Loop Gain Fine Adjustment (Unit: Multiple × 1000)
Return Value 0: Parameter setting successful
1: Parameter setting unsuccessful
Explanation
This parameter makes fine adjustments to the servo's loop gain (inertia of the motor
and mirror, and the torque constant of the motor are related).
and mirror, and the torque constant of the motor are related).
Note: This is usually set appropriately at shipping.
Related
Command
/Parameter
Command
/Parameter
Parameter ID
48
Parameter
Name
VR head1 AB offset
Data
A/B-phase offset of encoder VR adjustment head 1 (Unit: none)
Return Value 0: Parameter setting successful
1: Parameter setting unsuccessful
Explanation
This parameter is used to adjust the offset of encoder signal.
Note: This is usually set appropriately at shipping.
Related
Command
/Parameter
Command
/Parameter
Parameter ID
49
Parameter
Name
VR head1 A gain
Data
A-phase amplitude of encoder VR adjustment head 1 (Unit: none)
Return Value 0: Parameter setting successful
1: Parameter setting unsuccessful
Explanation
This parameter is used to adjust the A-phase amplitude of the encoder signal.
Note: This is usually set appropriately at shipping.
Related
Command
/Parameter
Command
/Parameter
Parameter ID
50
Parameter
Name
VR head1 B gain
Data
B-phase amplitude of encoder VR adjustment head 1 (Unit: none)
Return Value 0: Parameter setting successful
1: Parameter setting unsuccessful
Explanation
This parameter is used to adjust the B-phase amplitude of the encoder signal.
Note: This is usually set appropriately at shipping.
Related
Command
/Parameter
Command
/Parameter