Canon GM-1000 ユーザーズマニュアル

ページ / 140
 
CANON  Digital Galvano Scanner System  GM-1000 Series 
Users Manual 1.20 
 
 
 
  
37
2.8.5. RS-232C Communication Command Input and High-Speed Communication 
Switching 
A position command input can be switched with a RS-232C communication command. 
 
Command ID 
Data 
23 
0: RS-232C command communication 
    7: High-speed serial communication 
 
 
 
 
 
 
 
 
 
   
 
 
 
 
Note: In the case of two axis control, it is necessary to execute this command for each axis. 
 
It is possible to receive input of RS-232C communication commands even when switching to 
high-speed serial communication. However, as position commands give priority to the input of 
high-speed serial communication, operation commands such as RS-232C communication command 
step movement, and raster scans will be ignored.   
 
 
 
Command ID = 23      Data 7 
       
A1C023/7 
       
A2C023/7
Command ID = 23      Data 0 
       
A1C023/0 
       
A2C023/0 
High-speed serial 
communication 
RS-232C command 
communication 
*Command also sent to Axis 2 
*Command also sent to Axis 2