Canon GM-1000 ユーザーズマニュアル

ページ / 140
 
CANON  Digital Galvano Scanner System  GM-1000 Series 
Users Manual 1.20 
 
 
 
  
7
2.2. Controller (GC-201) 
Performance and Dimensions 
 GC-201 
Number of control axes 
Control sampling 
100 kHz 
Maximum drive current 
Peak 10 A (each axis) 
Interface 
RS-232C , High-speed serial communication(XY2-100) 
Notch filter 
Digital notch filter     ×2 
Digital low-pass filter    ×1 
Analog notch filter        ×2 
Weight 350 
 
Environmental conditions 
Operating temperature and humidity 
0 to 50ºC, 90% RH or less (No condensation) 
Storage temperature and humidity 
-20 to 60ºC, 90% RH or less (No condensation) 
Note: The above operating temperature and humidity conditions depend on the operating and heat 
radiation conditions. 
 
Section names 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
Heat radiation 
frame 
Mounting screw 
hole (M3 × 4) 
Digital board (upper) 
Analog board (lower) 
IF board 
Mounting screw 
hole (φ3.5 × 4)