Canon GM-1000 ユーザーズマニュアル

ページ / 140
 
CANON  Digital Galvano Scanner System  GM-1000 Series 
Users Manual 1.20 
 
 
 
  
74
6.3.  Operation that Synchronizes with External Trigger Signal input (Raster Scan)   
“4.3.    Raster Scan” can be operated in synchronization with an external trigger signal. 
 
The Movement Pattern 
There are two kinds of movement patterns. 
 
  (The raster scan of one coming and going operates whenever the external trigger signal is input.)
 
 
 
 
 
 
 
 
 
 
 
 
  (The raster scan of one way operates whenever the external trigger signal is input.) 
 
 
 
 
 
 
 
 
 
 
 
 
 and ②  operation pattern can be selected by RS-232C command (Command ID = 23 ‘Operation 
Mode setting‘) 
 
 
 
External Trigger Signal 
Raster Scan position 
(Current Angle Position) 
Angle 
Voltage 
 
External Trigger Signal 
Raster Scan position 
(Current Angle Position) 
Angle 
Voltage