Canon GM-1000 ユーザーズマニュアル

ページ / 140
 
CANON  Digital Galvano Scanner System  GM-1000 Series 
Users Manual 1.20 
 
 
 
  
75
Input the external trigger signal 
The external trigger signal is input from the digital I/O connector. 
(See 5-1 ‘Connector Pin Arrangement) 
 
Connector pin arrangement 
Pin 
No. 
Monitor Board 
Signal Name 
I/O Signal 
Description  Logic  Remarks 
B5 
10 Input 
External 
Trigger 
Signal 
High: ON 
See Circuit below.
   
 
Connection Specifications 
   
3.3V TTL  Input 
 
 
 
 
Operation procedure 
(Raster Scan Parameter Settings) 
Set Parameter ID =26 
Raster Scan Time   
Setting
 
Set Parameter ID =27 
Raster Scan Duty Ratio   
Setting
 
     
Set Parameter ID =28 
Raster Scan Angle   
Setting
 
(Raster Scan Operation) 
     
Send Command ID=8   
Data=6  Movement Start   
(Movement to the initial position 
       of 
raster 
scan) 
     
Send Command ID=23    Data=8  (One way scan)   
                    
 
Data=9  (One coming and going) 
                  
 
     (Reference: Data = 3 in case of continuous operation) 
        ・
Input the external trigger Signal
 
Send Command ID=23 
Data=0 Scan Stop
 
 
Notes 
・ 
The external trigger input during raster scan move is ignored. 
・ 
From the external trigger signal input, until the time actual operation starts, there can be a 
fluctuation of up to a maximum of 10 usec. 
FPGA 
3.3V-TTL 
R : 100Ω 
Connector 
Select either