IBM 5.5 ユーザーズマニュアル

ページ / 86
58
Configuring Netcool/OMNIbus process control
Netcool/OMNIbus process control allows the Netcool/Precision TN process to be 
monitored and automatically restarted if it exits unexpectedly. If Netcool/Precision TN is 
not configured to run using process control, it must be started or restarted manually using 
system init scripts or the command line.
To set up the process control daemon and agent, follow the instructions in the 
Netcool
®
/OMNIbus
 Administration Guide . 
Netcool/Precision TN is not PA Aware. To configure the process agent to monitor the 
Netcool/Precision TN process, add the following section to your 
$OMNIHOME/etc/process_agent_name.conf
 configuration file: 
nco_process 'PrecisionTN'
{
   Command '<netcool_install_dir>/bin/precisiontn' run as 0
   Host='my_host_name'
   Managed=true
   RestartMsg='Netcool/Precision TN has been restarted'
   AlertMsg='Netcool/Precision TN has gone down'
   RetryCount=0
   ProcessType=PaNOT_PA_AWARE
}
where <netcool_install_dir> is replaced with the Netcool installation directory (the 
default is /opt/netcool), and my_host_name is replaced with the hostname of the 
machine where Netcool/Precision TN is running. 
Disabling use of Netcool/OMNIbus
If you do not want event correlation and only want to perform asset polling, you can disable 
Netcool/OMNIbus. Netcool/Precision TN should always perform event correlation which 
requires the Netcool/OMNIbus ObjectServer.
You can configure Netcool/Precision TN not to use Netcool/OMNIbus by editing the 
precisiontn.xml
 file. 
Go to the <netcool_install_dir>/etc/precisiontn directory and open the 
precisiontn.xml
 file and change the "lumos.leap.service.opl.Enable" value to 
"false"
 to disable the Netcool/OMNIbus integration.
<properties name="LEAPFramework">
<property name="lumos.leap.service.opl.Enable" 
value="false" />
</properties>