5
WARNING
s  Make sure doorway is in view and clear of obstacles and 
people to avoid injury or damage to property.
s  DO NOT operate this unit from wall console before LIMITS 
and FORCE are set.  Severe damage to the opener can occur. 
s  The bullet MUST be engaged to carriage BEFORE setting  
limits.  See Installation Poster (if provided) or call 
Customer Service at 800-35-GENIE or visit 
www.geniecompany.com.
NOTE: If bullet has NOT been engaged to 
the carriage, do so no .
PROGR
2
Please note that there is a 30 second timeout between 
 each programming step.
If you see two flashing RED LEDs, you have initiated 
a timeout.
In the ev
w  See page 9.
CONTACT REVERSE TEST
 
The Force and Limit settings MUST be COMPLETED 
before performing Contact Reverse Test.
1.
 
Test.
 
Place a 2" x 4" 
board (laid flat) 
under center of 
door opening.
 
2. Adjustment, if needed.
s
 
WARNING
 
A moving door can cause serious injury or death.
1.   Keep people clear of opening while door is moving.
2.  Do 
NOT allow children to play with opener, including 
wall console, remote, or wireless keypad.
3.   During programming, door opener could begin to run, 
so stay away from moving door and its parts.
 
Once the Contact Revese Test is complete, 
continue with programming Remotes.
or it does not reverse, it may be due to an improperly set 
down limit. Repeat TRAVEL LIMITS program and Test again.
Repeat as needed until door passes test. For further help 
refer to Maintenance &Troubleshooting, page 13.
   
ent of a timeout you must restart at beginning. 
Press & hold 
2 seconds or until 
LEDs react. Release.
Press & hold 
2 seconds or until 
LEDs react. Release.
Long LED turns Blue, 
Round LED OFF.
Then Long LED OFF
Round LED Flashing.
Long LED turns Blue, then flashes.
Press & hold
until door  is fully 
open. Then release.
Press & 
Release.
DOOR LIMITS ARE SET
SET FORCE NEXT
PROGRAM
SET
 
FLASHING
DOOR FULLY OPEN
DOOR FULLY CLOSED
OFF
O
RED
RED
FF
Press & 
Release.
PROGRAM
SET
 
Press & 
Release the
Open/Close 
button.
DOOR CLOSES.
s  When door contacts board, 
   it must stop and reverse direction 
   (within 2 seconds) to the fully 
   open position.
OFF
OFF
AMMING LIMITS 
TRAVEL LIMITS
UP LIMIT
DOWN LIMIT
Door fully closes.
Door fully opens.
FORCE CONTROL
Press & 
Release
Open/Close 
button.
ACTION    
           INDICATION/RESULT
ACTION    
           INDICATION/RESULT
Press & 
Release
Open/Close 
button.
ON WALL CONSOLE
 
Press & 
Release the
Open/Close 
button.
FORCE CONTROL IS SET
1
2
1
2
1
3
4
5
6
2
3
DOOR OPENS.
ACTION    
                         LED INDICATION/RESULT
OFF
OFF
ON
BLUE 
BOTH FLASH BLUE
FLASHING
Press & hold
until door  is fully 
closed. Then release.
B
During the initial setting 
of the limits- the LEDs will 
turn to RED—NOT OFF
oth BLUE then LEDs Off confirms limit set.
OFF
OFF
BOTH FLASH BLUE
Both BLUE then LEDs Off confirms limit set.