Handling the high-pressure hose 
Cleaning the unit (shutting down)
6. 
Handling the high-pressure hose
The unit is equipped with a high-pressure hose specially suited for 
piston pumps.
Danger of injury through leaking high-pressure 
hose. Replace any damaged high-pressure hose 
immediately.
Never repair defective high-pressure hoses yourself!
The high-pressure hose is to be handled with care.  Avoid sharp 
bends and folds: the smallest bending radius is about 20 cm.
Do not drive over the high-pressure hose. Protect against sharp 
objects and edges.
Never pull on the high-pressure hose to move the device.
Make sure that the high-pressure hose cannot twist. This can be 
avoided by using a Wagner spray gun with a swivel joint and a hose 
system.
i
When using the high-pressure hose while working 
on scaffolding, it is best to always guide the hose 
along the outside of the scaffolding.
i
The risk of damage rises with the age of the high-
pressure hose. Wagner recommends replacing high-
pressure hoses after 6 years.
i
use only WAGNER original-high-pressure hoses in 
order to ensure functionality, safety and durability.
7. 
Interruption of work
  1.  Open the relief valve, valve position PRIME
   (k circulation).
  2.  Switch the unit OFF.
  3.  Turn the pressure control knob counterclockwise to minimum 
pressure.
  4.  Pull the trigger of the spray gun in order to release the 
pressure from the high-pressure hose and spray gun.
  5.  Secure the spray gun, refer to the operating manual of the 
spray gun.
  6.  If a standard tip is to be cleaned, see Page 17, Section 12.2.
 
  If a non-standard tip is installed, proceed according to the 
relevant operating manual.
  7.  Depending on the model, leave the suction tube or the 
suction hose and return hose immersed in the coating 
material or swivel or immerse it into a corresponding cleaning 
agent.
Attention
If fast-drying or two-component coating material is 
used, ensure that the unit is rinsed with a suitable 
cleaning agent within the processing time.
8. 
Cleaning the unit (shutting down)
A clean state is the best method of ensuring operation without 
problems. After you have finished spraying, clean the unit. Under no
circumstances may any remaining coating material dry and harden in 
the unit.
The cleaning agent used for cleaning (only with an igni tion point 
above 21 °C) must be suitable for the coating material used.
•  Secure the spray gun, refer to the operating manual of the 
spray gun.
Clean and remove tip.
For a standard tip, refer to Page 17, Section 12.2.
If a non-standard tip is installed, proceed according to the relevant 
operating manual.
  1.  Remove suction hose from the coating material.
 2.  Close the relief valve, valve position SPRAY (p spray).
  3.  Switch the unit ON.
  4.  Pull the trigger of the spray gun in order to pump the 
remaining coating material from the suction hose, high-
pressure hose and the spray gun into an open container.
Attention
The container must be earthed in case of coating 
materials which contain solvents.
Caution! Do not pump or spray into a container with 
a small opening (bunghole)!
Refer to the safety regulations.
  5.  Immerse suction hose with return hose into a container with a 
suitable cleaning agent.
 6.  Turn the pressure control knob into the blue zone - pulsating
pressure for unit cleaning.
  7.  Open the relief valve, valve position PRIME 
   (k circulation).
  8.  Pump a suitable cleaning agent in the circuit for a few 
minutes.
 9.  Close the relief valve, valve position SPRAY (p spray).
  10.  Pull the trigger of the spray gun.
  11.  Pump the remaining cleaning agent into an open container 
until the unit is empty.
  12.  Switch the unit OFF.
8.1 
Cleaning unit from outside
First of all pull out mains plug from socket.
Attention
Danger of short circult through panetrating water!
Never spray down the unit with high-pressure or 
high-pressure steam cleaners.
Attention
Do not put the high-pressure hose into solvents. 
use only a wet cloth to wipe down the outside of the 
hose.
Wipe down unit externally with a cloth which has been immersed in a 
suitable cleaning agent.