OPTIONAL ACCESSORIES
... sold separately
○  Pneumatic Tool Lubricant
 
.8 oz. (25 cc) oil feeder 
(Code No. 877153)
 
4 oz. (120 cc) oil feeder 
(Code No. 874042)
 
1 quart (1 ltr) can 
(Code No. 876212)
NOTE:  Accessories are subject to change without any 
obligation on the part of HITACHI.
APPLICATIONS
○  Floor and wall framing.
○  Truss build-up, Window build-up.
○ Subfl ooring and roof decking.
○ Wall sheathing.
○  Mobile home and modular housing construction.
BEFORE OPERATION
Read section titled “SAFETY” (pages 4 – 7).
Make sure of the followings before operation.
WORKING ENVIRONMENT
 WARNING
● No fl ammable gas, liquid or other fl ammable 
objects at worksite.
● Clear the area of children or unauthorized 
personnel.
AIR SUPPLY
 DANGER
●   NEVER use oxygen or other 
bottled gases. Explosion may 
occur.
 WARNING
● 
Never connect Nailer to pressure 
which potentially exceeds 200 psi 
(13.7 bar  14 kgf/cm
2
).
●  Never use non relieving coupler on Nailer.
1. Power 
source
○  Use only clean, dry, regulated compressed air as a 
power source for this Nailer.
○  Air compressors used to supply compressed air to 
this Nailer must comply with the requirements of 
the latest version of ANSI Standard B 19.3 “Safety 
Standard For Compressors For Process Industries.”
○  Moisture or oil in the air compressor may accelerate 
wear and corrosion in the Nailer.
 Drain 
daily.
2. Filter-Regulator-Lubricator
○  Use a regulator with a pressure range of 0 – 120 psi 
(0 – 8.3 bar  0 – 8.5 kgf/cm
2
).
○  Filter-regulator-lubricator units supply an optimum 
condition for the Nailer and extend the Nailer life.
 
These units should always be used.
Filter ............ The  fi lter removes moisture and dirt 
mixed in compressed air.
Drain daily unless fi tted with an 
automatic drain.
Keep the fi 
lter clean by regular 
 
maintenance.
Regulator ......The regulator controls the operating 
pressure for safe operation of the Nailer.
Inspect the regulator before operation to 
be sure it operates properly.
Lubricator .... The lubricator supplies an oil mist to the 
Nailer.
Inspect the lubricator before operation 
to  be  sure  the  supply  of  lubricant  is 
adequate.
Use Hitachi pneumatic tool lubricant.
Nailer Side
Filter
Lubricator
Compressor Side
Regulator
3. Air 
hose
  Air hose must have a minimum working pressure 
rating of 150 psi (10.4 bar  10.6 kgf/cm
2
) or 150% 
of the maximum pressure produced in the system, 
whichever is higher.
4. Air 
consumption
  Using the Air consumption table and the Air 
compressor size formula, fi nd a correct compressor 
size.
000Book_NR83AA4_US.indb   10