Hitachi NR 83AA4 ユーザーズマニュアル

ページ / 60
11
English
Air consumption table
Operating pressure
psi
(bar)
(kgf/cm
2
)
80
(5.5)
(5.6)
90
(6.2)
(6.3)
100
(6.9)
(7)
Air consumption
ft
3
/cycle
(Itr/cycle)
.062
(1.7)
.075
(2.1)
.088
(2.5)
Air compressor size formula
 
Amount of air required
 
=number of Nailers
  × average nails driven each minute per Nailer
  × air consumption at given air pressure
  × safety factor (always 1.2)
Example:   2 Nailers operating at 100 psi driving 30 
nails per minute
 
Amount of air required
 
=2 × 30 × .088 (2.5) × 1.2
 
=6.3 CFM (ft
3
/min) (180 ltr/min)
  After making the calculations as shown above, you 
should  fi nd a compressor providing 6.3 CFM of air 
that is required.
LUBRICATION
It is important that the Nailer be properly lubricated.
Without proper lubrication, the Nailer will not work 
properly and parts will wear prematurely.
○  Use Hitachi pneumatic tool lubricant.
 
Do not use detergent oil or additives. These lubricants 
will harm the O-rings and other rubber parts. This will 
cause the Nailer to malfunction.
○ Filter-regulator-lubricator units should always be 
used.
 
Keep the lubricator fi lled with Hitachi pneumatic tool 
lubricant.
○  If a lubricator is not available, supply 5 – 10 drops of 
Hitachi pneumatic tool lubricant into the air plug on 
the Nailer twice a day.
COLD WEATHER CARE
○  Do not store the Nailer in a cold weather environment.
  Keep the Nailer in a warm area until beginning the 
work.
○  If the Nailer is already cold, bring it in a warm area 
and allow the Nailer to warm up before use.
1 Reduce the air pressure to 64 psi (4.4 bar 
4.5 kgf/cm
2
).
2 Remove all nails from the Nailer.
3 Connect the air hose and free-fi re (blank-fi re) the 
Nailer.
  The lowered air pressure will be enough to free-
fi re the Nailer.
  Slow speed operation tends to warm up the 
moving part.
 CAUTION
●  Do not free-fi re the Nailer at high pressure.
TESTING THE NAILER
 DANGER
●   Operators and others in work 
area MUST wear safety 
glasses with side shields 
which conforms to ANSI Z87.1 
specifi cations.
 WARNING
● Never use Nailer unless push lever is 
operating properly.
Before actually beginning the nailing work, test the Nailer 
by using the checklist below. Conduct the tests in the 
following order.
If abnormal operation occurs, stop using the Nailer and 
contact a Hitachi authorized service center immediately.
(1)  DISCONNECT AIR HOSE FROM NAILER.
 
REMOVE ALL NAILS FROM NAILER.
□  ALL SCREWS MUST BE TIGHTENED.
  If any screws are loose, tighten them.
□  THE PUSH LEVER AND TRIGGER MUST MOVE 
SMOOTHLY.
Push Lever
Trigger
Do not connect 
air hose
000Book_NR83AA4_US.indb   11
000Book_NR83AA4_US.indb   11
2013/04/23   15:04:13