Hitachi NR 83AA4 ユーザーズマニュアル

ページ / 60
13
English
(3)  Pull the nail feeder (B) back to engage the nail feeder 
(A) to the nail strip.
Nail Feeder (B) 
Nail Feeder (A)
NOTE: 
  Quietly push the Nail Feeders (A) and (B) against the 
nail.
  If the Nail Feeders (A) and (B) are released from 
backward the magazine and bumped against the nail, 
the connecting paper of the nail can be damaged.
  Use nail strip of more than 5 nails.
The Nailer is now ready to operate.
Removing the nails:
1  Pull the nail feeder (B) backward.
2 Return the nail feeder (B) forward quietly while 
pushing the nail feeder (A).
3  Push the nail stopper toward the magazine side, and 
pull out nails from the back of the magazine.
1
2
2
Nail Feeder (A)
Nail Feeder (B)
ADJUSTING AIR PRESSURE
 WARNING
●   Do not exceed 
120 psi (8.3 bar 
8.5 kgf/cm
2
).
Adjust the air pressure at recommended operating 
pressure 70 – 120 psi (4.9 – 8.3 bar  5 – 8.5 kgf/cm
2
according to the length of nails and the hardness of 
workpiece.
The correct air pressure is the lowest pressure which will 
do the job. Using the Nailer at a higher than required air 
pressure unnecessarily over stresses the Nailer.
LOADING NAILS
 WARNING
●  When loading nails into Nailer,
1)  do not pull trigger;
2)  do not depress push lever; and
3)  keep Nailer pointed downward.
(1)  Insert nail strip into rear of magazine.
Magazine
(2)  Slide the nail strip forward in the magazine.
 
The nail strip should pass the nail stopper.
Nail Stopper
000Book_NR83AA4_US.indb   13
000Book_NR83AA4_US.indb   13
2013/04/23   15:04:13
2013/04/23   15:04:13