If the SIDE BARS (only)  flash AND other icons are lit and not 
flashing, this indicates the battery has requested to be fully charged 
and discharged in order to update its “learned capacity”.  This 
“learning” should typically occur during normal equipment operation. 
However, if the battery has not been fully charged and discharged for 
some time, this indication will appear. 
To remove the flashing SIDE BARS, fully charge the battery 
(STEADY GREEN indication) on the InterActive 2000 charger. 
Then either: 
(a)  Discharge the battery on a camera in normal operation 
continuing to keep the camera “hot” until it shuts down. Then 
return the battery to the charger. When the battery is full remove 
it from the charger.  
(b)  This can be done automatically with an InterActive2000 
PowerCharger with a DDM (Diagnostic Discharge Module 
installed.  This unique feature is called “AUTOCAL” and is 
included as standard on QUAD 2702 and DUAL 2722 
PowerChargers. (Please reference the appropriate PowerCharger 
Owner’s Manual.) 
IMPORTANT NOTE: The flashing SIDE BARS indication is not a 
warning indication.  The battery will operate perfectly normal while 
awaiting a “learning” cycle. Rather than relying on an “assumed” 
capacity, as with some imitation fuel gauges, the DIONIC 90 battery 
relies on the Digital Battery electronics to update capacity 
information as the battery sees different operating conditions and 
ages normally. The flashing bars are merely an indication that the 
battery has not updated this information for some time and is 
requesting a confirmation of its “learned” capacity.