Toshiba e-Studio160 サービスマニュアル
![Toshiba](https://files.manualsbrain.com/attachments/acaaaa9cc6b763ccfc72ced2ae95d9c94b8b8632/common/fit/150/50/8adbcbcd45c75dc53932fc9caf6f2740daed52d836b76efbd0162ac2599f/brand_logo.png)
December 2002 TOSHIBA TEC
1 - 93
e-STUDIO160/200/250 ADJUSTMENT
: Turn the transfer guide bias ON.
Measure the transfer guide bias at the following two points:
Important:
The settings and conditions of the digital tester to be used for measurement are as
follows:
Function switch: DC
Full scale:
1000V
Remark:
The digital tester to be used should have an input resistance
value of 10M
Ω
or more.
Measurement value: +375
±
20V
To measure on the pinch roller:
CLEAR/STOP
START
01-11-02
To measure on the paper guide plate:
From preceding page
: Turn the transfer guide bias OFF.
: End the output test.
01-11-03
CANCEL
CANCEL
Power OFF
Frame grounding
terminal
Pinch roller
terminal
Frame grounding
terminal
terminal
Paper guide plate