Testing Procedures 
 
!
WARNING
 
To avoid risk of electrical shock, personal injury or death; disconnect power and gas to oven before servicing, 
unless testing requires power and/or gas. 
 
©2004 Maytag Services 
16023415 
17 
Component Testing 
Illustration Component 
Test 
Procedure 
Results 
 
 
Oven light housing 
Disconnect connector and test 
resistance of terminals .........................
 
Measure voltage at oven light: ............. 
Verify bulb is properly installed. 
Indicates continuity with bulb installed. 
 
120 VAC, refer to wiring diagram for 
terminal identification. If no voltage is 
present at light, check wiring/switches. 
 
 
Door plunger switch 
Remove switch from unit and measure 
the following points: 
C NO ................................................ 
 
 
Plunger in continuity, Plunger out infinite. 
 
 
Autolatch assembly 
with switch 
Disconnect wires and test for 
continuity per wiring diagram. 
 
Refer to Parts Manual for correct 
autolatch switch associated with the 
correct manufacturing number. 
See wiring diagram for schematic layout. 
Access assembly by removing left side 
panel. 
5 K btu 
9.2 K btu 
16 K btu  
12 K btu (Model 
MGR6875AD*) 
270
° valve 
 
Verify gas is supplied. 
 
Adjust set screw for simmer control. 
 
 
 
Spark 270
° switch 
Test for voltage at terminals.................
 
Disconnect wiring and check for 
continuity in LITE position .................... 
120 VAC 
 
 
Continuity in LITE position. 
 
 
Spark ignition 
electrode 
Test for resistance of spark lead..........
 
Test ignitor to chassis .......................... 
Continuity 
 
No continuity from ignitor to chassis. 
5 K btu 
9.2 K btu 
16 K btu 
12 K btu (Model 
MGR6875AD*) 
Top surface burner 
 
Verify gas is supplied ...........................
 
Verify burner cap is positioned 
correctly. 
 
Check for obstructions in burner ports. 
 
L
A
B
A1
B1
N
 
Spark module 4 + 0 
Test for voltage at terminals L and N ... 
 
Check polarity and ground ................... 
120 VAC 
 
See wiring diagram 
 
 
Temperature sensor 
Measure resistances............................
 
Approximately 1100 
Ω at room 
temperature 75
°F. 
 
 
Bake burner 
Verify gas is supplied. 
 
Orifice adjusted for Natural or LP.........
 
Check for obstructions or 
contamination in ports.......................... 
Set for Natural Gas from the factory 
 
Adjust as necessary. 
 
 
Replace if punctured or torn. 
 
 
Broil burner 
Verify gas is supplied. 
 
Orifice adjusted for Natural or LP.........
 
Check for obstructions or 
contamination in ports.......................... 
Set for Natural Gas from the factory 
 
Adjust as necessary. 
 
 
Replace if punctured or torn. 
 
 
Ignitor 
Test for voltage at terminals.................
 
Test for the amount of amperage in the 
circuit ...................................................
(Ignitor may glow but not have 
sufficient amperage to open valve). 
120 VAC 
 
 
3.2 
− 3.6 Amps If not replace.