Testing Procedures 
 
!
WARNING
 
To avoid risk of electrical shock, personal injury or death; disconnect power and gas to oven before servicing, 
unless testing requires power and/or gas. 
18 
16023415 
©2004 Maytag Services 
 
 
Illustration Component 
Test 
Procedure 
Results 
 
 
Triple thermal valve 
Disconnect wiring to valve. 
Measure resistance on upper and 
lower bake circuit.................................
Measure resistance on broil circuit ......
 
 
Continuity, If not replace. 
Continuity, If not replace. 
 
WARNING
!
 
      Do not attempt to open valve with 
                         120 VAC. 
 
 
 
Pressure regulator 
Verify gas pressure (W.C.P.). 
 
If on LP service verify proper gas 
supply conversion. 
5" Natural 
10" LP/propane 
 
 
Shut off valve 
Check to verify gas supply is turned 
on. 
Located on surface valve manifold 
near maintop upsweep. 
Gas ON .... slot at 9 o’clock position 
Gas OFF... slot at 12 o’clock position 
 
Model MGR6875AD* 
Convection Assembly 
Convection Element 
Convection Motor 
Measure voltage..................................
Remove wires, check resistance .........
Check motor windings to ground .........
120 VAC. 
Approximately 28 to 33 
Ω. 
No continuity. 
Approx. 900 RPM. 
 
Power cord 3-wire 
Verify resistance of wires to 
terminals. 
Continuity