Electrolux WT30H208DU ユーザーズマニュアル

ページ / 18
ENGLISH
9
A fused disconnect switch or a main circuit breaker 
(customer furnished) MUST be installed in the 
electric supply line for the appliance. It is recom-
mended that this switch/circuit breaker have 
lockout/tagout capability. Before making any electri-
cal connections to this appliance, check that the 
power supply is adequate for the voltage, amperage, 
and phase requirements on the rating plate.
RATING PLATE
The rating plate contains identification and technical 
data and is located on the right-hand side panel of the 
appliance (Figure 5).
Figure 5
C1
WATER CONNECTION
• Position the dishwasher and level the appliance by 
adjusting the appropriate bullet feet (Figure 5).
• Connect the appliance water supply pipe “A” 
(Figure 4) (keeping with local plumbing codes) to the 
incoming water supply. Install a shutoff valve, Y-
Strainer, and a pressure gauge between the appli-
ance and the incoming water supply of the unit 
(Figure 6).
• In models with incorporated water softener, connect 
the double non-return valve "B" (Figure 6) supplied 
and the machine supply pipe.
Figure 6
Check that the dynamic water supply pressure measures 
between 
7.25 - 101 psi/50 - 700kP
while dishwasher 
tank or boiler is filling with water. 
If the pressure is too high, install a suitable pressure 
regulator on the incoming water supply to the unit.
Position the outlet pipe at a height anywhere between 29 
1/2” to 39 3/8”/750 to 1000mm from the floor.
Check that about 1 gallon/4 litres of water flow out of the 
outlet pipe during the rinse cycle.
Make sure drain hose does not kink, pinch or twist, 
resulting in a water flow restriction.
C2
ELECTRICAL CONNECTION
Figure 7
The installation of this unit must conform to local 
codes or, in the absence of local codes, to all Natio-
nal Codes governing plumbing, sanitation, safety 
and good trade practices.
• Check the over rating plate before making any 
electric supply connections. Electric supply connec-
tions must agree with data on the unit rating plate.
• The earth wire at the terminal end must be 
3/4”/20mm (max.) longer than the phase wires.
• The appliance requires a ground connection to the 
unit ground screw located at the rear of the unit 
marked “Q” (Figure 4) in the manual and marked with 
the symbol “ “ on the unit. The ground wire must 
have a cross section of AWG 8/8.35 mm
2
. Do not use 
the wiring conduit or other piping for ground connec-
tions. If necessary, have the electrician supply the 
ground wire.
C
INSTALLATION AND START-UP INSTRUCTIONS
Model LS6 
PNC 9CGX 502003  05   Ser.N .123000001
AC 400V 3N                50Hz
Power Boiler              16500w
Power Tank                 7500w
Power Max                26800w
       Made in EEC
Model RT10 ED
PNC    9CGX502003 05
Ser.N .123000001
!
B
CAUTION
 
THE ELECTRICAL CONNECTIONS 
MUST MEET ALL NATIONAL AND 
ELECTRICAL CODE REQUIREMENTS.
AC  400....
1
11
10
9
8
7
6
5
4
3
2
12
!