Electrolux EKM 90310 X ユーザーズマニュアル

ページ / 8
7
E 14
25 W - 230 V~
T300°C
A
GB
IMPORTANT
The wires in the mains 
cable
 are coloured 
as follows
:
GREEN AND YELLOW........EARTH
BLUE....................................NEUTRAL
BROWN ...............................LIVE
REPLACING 
OF THE CABLE
If
 the cable 
becomes
 damaged 
or worn
, replace it, 
observing
 the
following instructions:
- open the box of the supply board as 
shown
 
in
 the 
diagram
 below;
- unscrew screw “A” 
that secures
 the cable;
- replace the cable with one of the same
 length
 and 
which corresponds
to
 the features described 
in
 the table; switch the appliance off, and
shut 
the gas tap;
connect
 the ‘green-yellow” earth wire to the terminal “      “, leaving
it approximately
 10 mm longer 
than
 the live 
wire
;
connect
 the “blue” neutral wire 
to the terminal marked “N”
;
connect 
the live wire 
to the terminal marked “L”
.
Always isolate the cooker from the electricity supply, 
shut 
off the gas
supply temporarily and proceed as follows.
- change the injectors,
- adjust the minimum flow of the burners.
REPLACEMENT OF
 COOKTOP
 INJECTORS
To change
 the 
cooktop
 injectors,
 proceed
 as follows: remove the
grids, remove burners and flame-spreaders (see fig.A), change the
injector (see fig.B) and replace it with another one suitable for the
new type of gas (see table D). Re-assemble everything in 
reverse
order
ensuring you position
 the flame-spreader 
correctly
.
This appliance must be installed by a qualified person in
accordance with the 
latest IEE
 Regulations and in compliance
with the 
manufacturer’s
 instructions.
Check
 that the voltage is the same as that stated on the rating plate.
The rating plate
 is located 
on the back cover.
WARNING! THIS APPLIANCE MUST BE EARTHED
If an fixed appliance is not equipped with supply cable and plug, the
power supply must be fitted with a disconnect switch in which the
distance between contacts permits total disconnection in accordance
with overvoltage category III, as required by installation regulations.
We recommend that the cooker circuit is rated to 13 amps.
Cable type HO5 RRF  3 X 1.5 mm
2
Connecting the mains cable
Open the mains terminal block cover as shown, unscrew screw “A”
the cable clamp
,
 and 
loosen
 the screws in the mains terminal block
“L N E” which secure the three
wires of the mains cable. Fit the
cable and refit screw “A”
,
 the cable
clamp.
Allow sufficient cable length for the
cooker to be pulled out for cleaning,
but do not let it hang
 lower
 than
50mm (2”) 
from
 the floor. The cable
can be looped if necessary, but
make sure that it is not kinked or
trapped when the cooker is in
position.
A
B
Fig. 11
MINIMUM FLOW ADJUSTMENT FOR 
COOK
TOP TAPS
To adjust the minimum, 
proceed
 as follows: switch the burner on, and
turn the knob towards the minimum flow position    
Remove the knob
from the tap, introduce a 
small
 screwdriver in 
to
 the tap rod (fig. 11).
Attention: in taps with security valve, the minimum 
adjustment
 screw
“Z” is placed outside the 
tap
 rod (fig. 12).
WARNINGS
Isolate the cooker from the electricity supply before attempting to
replace the oven lamp.
The oven lamp 
is of a special type 
designed to
 withstand high
temperatures. To replace it, 
proceed 
as follows: 
remove 
the protect
ive
glass (A) and replace the burn
t-out
 
bulb
 with one of the same type.
Re
-fit
 the protecti
ve
 glass.
DISMANTLING THE COOKTOP
If it 
becomes
 necessary to repair or replace 
internal
 components,
proceed 
as follows: remove the glass lid from its position 
by sliding
off upwards.
Remove the grids, 
the 
burners and flame-spreaders (see   fig. 13),
unscrew the visible screws “V” 
located 
on the 
cooktop
 (see fig. 14).
Dismantle the cooktop
 by unscrewing the 4 rear screws “A” (see fig.
15 ).
Loosen
 the 
adjustment 
screw in order to increase the flow or 
tighten
it to decrease the flow.
The proper adjustment is obtained when the flame is 
approximately
3 or 4 mm 
in length
.
For butane/propane gas, the
 adjustment 
screw must be 
fully
 screwed
down
.
Make sure that the flame does not go out 
when 
passing quickly from
the max. flow 
     
to the minimum flow      .
Assemble the knob again.
Fig. 12
Z
Values referred to Hs - 15°C - 1013,25mbar
TAB. D
Cat. II 2H3+
                TABELLA GENERALE INIETTORI
Kind of gas
  mbar  
Nozzle
    
Burners
        
Power
 KW           Consum
             N°                          max.     min.   max.       min.
                          115    
Rapide
           3,00     0,75   286 l/h     72 l/h   reg.
NATURAL     20        97    
Semi rapide
   1,75     0,48   167 l/h     46 l/h   reg.
G 20                          72    
Auxiliary
        1,00     0,33     95 l/h     31 l/h   reg.
                               128    
Triple crown
   3,30     1,30    315 l/h   124 l/h   reg.
BUTANE    28-30    85     
Rapide
           3,00      0,75  219 g/h    55 g/h   42
G 30                        65     
Semi rapide
   1,75      0,48  128 g/h    35 g/h   31
                            50     
Auxiliary
        1,00      0,33     73 g/h    24 g/h  27
PROPANE    37       93    
Triple crown
   3,30     1,30   241 g/h    95 g/h   60
         G 31
By pass
ELECTRICAL CONNECTION
GAS ADJUSTMENT
APPLIANCE MAINTENANCE