Henny Penny OFE/OFG-321 ユーザーズマニュアル

ページ / 29
 Model OFE/OFG-321,322,323,324 
 
 
 
 
 
 
 
 
 
 
 
 
2-3 HIGH TEMPERATURE  
      LIMIT CONTROL  
     (Continued) 
 
 
 
 
 
 
3.  Remove the two nuts securing the high limit bracket to the unit  
 
 
 
 
 
      and pull the bracket from the unit. 
 
4.  Remove the two screws securing the high limit to the bracket, 
and remove the high limit from the bracket. 
 
5.  Remove the two electrical wires from the high temperature 
limit control. 
 
6.  Manually reset the control, then check for continuity between  
the two terminals after resetting the control. If the circuit is 
open, replace the control, then continue with this procedure. 
(If the circuit is closed, the high limit is not defective. Re- 
connect the two electrical wires.)  
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
Replacement: 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
  
To avoid electrical shock or property damage, move the  
 
POWER switch to OFF and disconnect main circuit  
      breaker, 
or 
unplug 
cord 
at 
wall 
receptacle. 
 
1.  If the tube is broken or cracked, the control will open, shutting 
off electrical power to the heat circuit. The control cannot be 
reset, and it will continuously click when pushed. 
 
2.  Drain the shortening from the frypot and discard. A substance 
in the tube could contaminate the shortening.  
 
3.  Remove the control panel. 
 
4.  Loosen small inside screw nut on capillary tube. 
 
 
 
 
 
2-2 
             
 
 
 
 
 
203