 Model OFE/OFG-321,322,323,324 
 
 
 
 
 
 
 
 
 
 
 
 
2-3 HIGH TEMPERATURE  
      LIMIT CONTROL  
     (Continued)
 
5.  Remove the bracket from the heat tube covering the high limit 
bulb. 
 
6.  Straighten the capillary tube behind the pot wall. 
 
7.  Pull the high limit bulb through the retainers on the heat tube. 
 
8.  Remove the larger outside nut that threads into the pot wall. 
 
9.  Remove the defective high limit from the control panel area. 
 
10. Insert new high limit into bracket and replace wires.  
 
11. Uncoil capillary line, starting at capillary tube, and insert 
through frypot wall. 
 
 
 
 
 
 
 
 
 
To avoid electrical shock or other injury, run the capillary 
line under and away from all electrical power wires and 
terminals.  The tube must never be in such a position where 
it could accidentally touch the electrical power terminals.
 
 
12. Insert capillary line through brackets on heat tube, and then  
pull back through pot wall until capillary bulb is secure in 
brackets. 
 
13. Pull excess capillary line from pot and tighten nut into 
frypot wall. 
 
14. With excess capillary line pulled out, tighten smaller nut. 
 
15. Replace bracket on heat tube covering the high limit bulb. 
 
16. Replace front panel. 
 
17. Refill frypot with shortening. 
 
 
 
 
 