Manitowoc Ice QM30 Series ユーザーズマニュアル

ページ / 28
 
 
 
Section 3 
Ice Machine Operation
3-1 
Section 3 
Ice Machine Operation 
 
Sequence of Operation 
 
Control Board Relays 
 
Ice Making 
Sequence of 
Operation 
Compressor 
Hot Gas Valve 
Water Fill Valve 
Water Pump 
Fan Motor 
Length of  
“ON” Time 
Start-Up
1
 
1.  Water Purge 
Off On  Off 
2.9 Minutes 
(175 Seconds) 
2.  Refrigeration 
System Start-Up 
On On  Off 
Seconds 
3.  Freeze Cycle 
On Off  On 
Automatically 
determined 
4.  Harvest Cycle 
On On  Off 
Automatically 
determined 
5.  Auto Shut-Off 
Off Off  Off 
Until bin thermostat  
re-closes 
Initial Start-Up or Start-Up After Automatic Shut-Off 
INITIAL START-UP OR START-UP AFTER 
AUTOMATIC SHUT-OFF 
1. Water Purge 
The water fill valve and the hot gas valve are 
energized for 2.9 minutes (175 seconds). This 
ensures that the ice making cycle starts with fresh 
water, and that the refrigerant pressures are 
equalized prior to refrigeration system start-up. 
2. Refrigeration System Start-Up 
The compressor starts 2.9 minutes (175 seconds) 
after the water fill valve and hot gas valve are 
energized. (The water fill valve and hot gas valve 
remain energized for 5 seconds during compressor 
start-up, and then shut off.) The compressor remains 
on throughout the entire freeze and harvest cycles. 
3. Freeze Cycle 
The condenser fan motor and water pump are 
energized and remain on throughout the entire 
freeze cycle. An even flow of water is directed 
across the evaporator and into each cube cell, where 
it freezes. 
The control system automatically determines the 
length of the freeze cycle by monitoring the 
temperature of the refrigeration system liquid line. 
4. Harvest Cycle 
The condenser fan motor and water pump de-
energize. The water fill valve energizes to purge the 
water in the water trough. The hot gas valve also 
energizes at the beginning of the harvest cycle to 
divert hot refrigerant gas into the evaporator. The 
hot refrigerant gas warms the evaporator, causing 
the cubes to slide, as a sheet, off the evaporator and 
into the ice storage bin. 
The control system automatically determines the 
length of the harvest cycle, based on the 
temperature of the refrigeration system liquid line at 
the end of the freeze cycle. At the end of the harvest 
cycle, the ice machine returns to another freeze 
cycle (step 3, above). 
5. Automatic Shut-Off 
The level of ice in the ice storage bin controls the 
ice machine shut-off. When the bin is full, ice cubes 
contact the bin thermostat bulb holder, which cools 
down and opens to stop the ice machine. The ice 
machine remains off until enough ice has been 
removed from the bin. This causes the thermostat 
bulb holder to warm and close, restarting the ice 
machine. When the ice machine restarts, it returns 
to the start-up sequence (steps 1 and 2, above).