INSTALLATION REQUIREMENTS
Tools and Parts
Gather the required tools and parts before starting installation. 
Read and follow the instructions provided with any tools listed 
here.
Tools Needed
Jigsaw or keyhole saw
Drill
³⁄₁₆" (5 mm) drill bit for pilot holes
Pencil
Tape measure or ruler
¹⁄₈" Flat-blade screwdriver 
Phillips screwdriver
½" and 
⁹⁄₁₆" Open-end wrenches or adjustable wrench 
1¼" (32 mm) drill bit
Level
Metal snips
Wire stripper or utility knife
Caulking gun and weatherproof caulking compound
Parts Supplied
Remote control with batteries
2 - Grease filters 
Top frame
Frame support
12 - 4 x 10 mm flat-head screws
10" (25.4 cm) diameter vent collar
Vent collar mounting frame (attached)
Remote up/down switch
4 - Cable tie mounting bases
4 - Cable ties
Curved glass panel
4 - Leveler feet with nuts
2 - Undercounter mounting brackets
8 - 5 mm x 12 mm pan-head screws
6 - 4 x 20 mm wood screws
Parts Needed
UL listed or CSA approved ½" (12.7 mm) conduit connector
Wall or roof cap with damper to match vent system
Vent system
Wiring cable for remote blower kit
Vent clamps/duct tape
Blower motor system (see the “Accessories” section for 
information on ordering)
Location Requirements
NOTE: Downdraft vent is installed directly behind the cooktop. 
For ease of installation, install the downdraft vent system first, 
then install the cooktop.
IMPORTANT: Observe all governing codes and ordinances.
Have a qualified technician install the downdraft vent. It is the 
installer’s responsibility to comply with installation clearances 
specified on the model/serial rating plate. The model/serial 
rating plate is located on the front of the downdraft vent.
Downdraft vent location should be away from strong draft 
areas, such as windows, doors, and strong heating vents or 
fans.
Cabinet opening dimensions that are shown must be used. 
Given dimensions provide minimum clearance. 
Consult the cooktop manufacturer Installation Instructions 
before making any cutouts. 
Check that the downdraft vent and cooktop location will 
clear the cabinet walls, backsplash, and rear wall studs 
inside the cabinet. 
Check for the minimum distance between the front edge 
of the countertop and the front edge of the cooktop. The 
minimum horizontal distance between the overhead 
cabinets is the same as the width of the installed 
downdraft vent.
All openings in ceiling and wall where the downdraft vent will 
be installed must be sealed.
Grounded electrical outlet is required. See “Electrical 
Requirements” section.
For Mobile Home Installations
The installation of this downdraft vent must conform to the 
Manufactured Home Construction Safety Standards, Title 24 
CFR, Part 328 (formerly the Federal Standard for Mobile Home 
Construction and Safety, title 24, HUD, Part 280) or when such 
standard is not applicable, the standard for Manufactured Home 
Installation 1982 (Manufactured Home Sites, Communities and 
Setups) ANSI A225.1/NFPA 501A, or latest edition, or with local 
codes.