Furuno 2839S ユーザーズマニュアル

ページ / 130
5.  INPUT/OUTPUT DATA
5-2
5.3
IEC 61162 Sentences
Input sentence and priority
Output sentences
Data
Format priority
Position
GNS>GGA>RMC>GLL
Speed (STW)
VBW>VHW
Speed (SOG)
VBW
Speed (position)
VTG>RMC
Heading (True)
THS>HDT
Time and Date
ZDA
Datum
DTM
Acknowledge alarm
ACK
UAIS VHF Data-link Message
VDM
UAIS VHF data-link Own-vessel report
VDO
AIS addressed and binary broadcast acknowledgement
ABK
Wind Speed and Angle (True)
MWV (T)
Wind Speed and Angle (Relative)
MWV (R)
Depth
DPT>DBT
Water Temperature
MTW
Set and Drift
CUR>VDR
Set alarm state
ALR
Data
Format
Own ship data
OSD
Radar system data
RSD
Set alarm state
ALR
TT target data
TTD, TLB, TTM
Addressed Binary and safety related Message
ABM
AIS Broadcast binary message
BBM
Voyage Static Data
VSD
General event message
EVE
Acknowledge alarm
ACK