Mitsubishi Electronics FR-A701 ユーザーズマニュアル

ページ / 259
105
V/
F
 p
a
tt
er
n m
a
tc
hi
ng 
applicat
ions
14
Load pattern selection
1
0
0
For constant-torque load
1
For variable-torque load
2
For constant-torque lift
Boost for reverse rotation 
0%
3
Boost for forward rotation 
0%
4
RT signal ON.... For constant-torque load (Same as 
in setting 0)
RT signal OFF .. For constant-torque lift
Boost for reverse rotation 0%
(Same as in setting 2)
5
RT signal ON.... For constant-torque load (Same as 
in setting 0)
RT signal OFF .. For constant-torque lift
Boost for forward rotation 0%
(Same as in setting 3)
Jog operat
ion
15
Jog frequency
0.01Hz
5Hz
0 to 400Hz Set the frequency for jog operation.
16
Jog acceleration/
deceleration time
0.1/
0.01s
0.5s
0 to 3600/
360s
Set the acceleration/deceleration time for jog 
operation. Set the time taken to reach the frequency 
set in Pr. 20 Acceleration/deceleration reference 
frequency
 for acceleration/deceleration time. (Initial 
value is 60Hz)
In addition, acceleration/deceleration time can not be 
set separately.
Logic
 selec
tion 
of
 out
p
ut
 st
o
p
 
signal (MR
S)
17
MRS input selection
1
0
0
Open input always
2
Normally closed input (NC contact input 
specifications)
4
External terminal:Normally closed input (NC contact 
input specifications)
Communication :Normally open input 
18
Refer to Pr. 1 and Pr. 2.
19
Refer to Pr. 3.
20, 21
Refer to Pr. 7 and Pr. 8.
Func
tio
n
Parameter
Name
Incre
ments
Initial 
Value
Range
Description
Re
la
te
d
 
p
ara
m
e
te
rs
V/FV/FV/F