Auxiliary functions (Pr. 156, Pr. 157)
P
A
RAMETERS
3
3.17.2 OL signal output timer (Pr. 157
)
<Setting>
Refer to the following table and set the parameter.
CAUTION
• When torque limit (stall prevention) activates, acceleration/deceleration may not be made according to 
the preset acceleration/deceleration time. Set Pr. 156 and stall prevention operation level to the 
optimum values.
• In vertical lift applications, make setting so that the fast response current limit is not activated.
 
Torque may not be produced, causing a drop due to gravity.
CAUTION
Always perform test operation.
Stall prevention operation performed during acceleration may increase the acceleration time.
Stall prevention operation performed during constant speed may cause sudden speed changes.
Stall prevention operation performed during deceleration may increase the deceleration time, 
increasing the deceleration distance.
Use this parameter to set whether the overload alarm signal (OL signal) is output immediately or a preset 
period of time after occurrence of an overload status.
Parameter
Name
Factory Setting
Setting Range
Remarks
157
OL signal output timer
0s
0 to 25s, 9999
9999: No signal output
Pr. 157 Setting
Description
0
Output immediately.
0.1 to 25
Output after the set time (s) has elapsed.
9999
Overload alarm signal is not output.
Related parameters
• OL signal terminal assignment 
⇒ Set 3 in any of Pr. 190 to Pr. 192, Pr. 195 (output terminal function selection). (Refer to page 152.)
Pr.158
Refer to Pr. 54 (page 97).
speed
torque
position
Overload status 
(OL action)
OL output signal
Set time (s)
V/F control .......... On when stall prevention operation level is exceeded.
Speed control ......On when torque limit is activated.
Torque control ..... On when speed limit is activated.
Position control ... On when torque limit is activated.