Mitsubishi Electronics FR-F700-NA ユーザーズマニュアル

ページ / 416
175
Frequency setting by analog input (terminal 1, 2, 4)
4
4.16.2 Analog input compensation (Pr. 73, Pr. 242, Pr. 243, Pr. 252, Pr. 253)
The above parameters can be set when Pr. 160 User group read selection = "0". (Refer to page 190)
(1) Added compensation (Pr. 242, Pr. 243)
Auxiliary input characteristics
A fixed ratio of analog compensation (override) can be made by the added compensation or terminal 2 as an
auxiliary input for multi-speed operation or the speed setting signal (main speed) of the terminal 2 or terminal 4.
Parameter 
Number
Name
Initial Value
Setting 
Range
Description
73
Analog input selection
1
0 to 3, 6, 7, 10 
to 13, 16, 17
Added compensation
4, 5, 14, 15
Override compensation
242
Terminal 1 added compensation 
amount (terminal 2)
100%
0 to 100%
Set the ratio of added compensation 
amount when terminal 2 is the main speed.
243
Terminal 1 added compensation 
amount (terminal 4)
75%
0 to 100%
Set the ratio of added compensation 
amount when terminal 4 is the main speed.
252
Override bias
50%
0 to 200%
Set the bias side compensation value of 
override function.
253
Override gain
150%
0 to 200%
Set the gain side compensation value of 
override function.
Added compensation 
connection example
⋅ The compensation signal can be input for the main speed setting for
synchronous/continuous speed control operation, etc.
⋅ Setting any of "0 to 3, 6, 7, 10 to 13, 16, 17" in Pr. 73 adds the voltage across
terminals 1 and 5 to the voltage signal across terminals 2-5.
⋅ If the result of addition is negative, it is regarded as 0 at the Pr. 73 setting of
any of "0 to 3, 6, 7", or reverse rotation operation (polarity reversible
operation) is performed when the STF signal turns ON at the Pr. 73 setting of
any of "10 to 13, 16, 17".
⋅ The compensation input of the terminal 1 can also be added to the multi-
speed setting or terminal 4 (initial value 4 to 20mA).
⋅ The added compensation for terminal 2 can be adjusted by Pr. 242, and the
compensation for terminal 4 by Pr. 243.
Analog command value using terminal 2 
= Terminal 2 input + Terminal 1 input 
×
 
Analog command value using terminal 4 
= Terminal 4 input + Terminal 1 input 
×
 
10
2
5
Forward 
rotation
Inverter
STF
1
Auxiliary input 
0 to    10V(   5V)
SD
Pr. 242
100(%)
Pr. 243
100(%)
Output frequency
When voltage across 
terminals 2 and 5 is 2.5V
(5V)
When voltage 
across terminals 
2 and 5 is 0V
+5V
(+10V)
Terminal 1
0
-2.5V
(-5V)
-5V
(-10V)
STF Signal
ON
STF Signal
ON
Forward rotation
Forward rotation
(a) When 
Pr. 73 setting is 0 to 5
Output frequency
When voltage across 
terminals 2 and 5 is 2.5V
(5V)
When voltage 
across terminals 
2 and 5 is 0V
+5V
(+10V)
Terminal 1
0
-2.5V
(-5V)
-5V
(-10V)
Forward rotation
Forward rotation
(b) When 
Pr. 73 setting is 10 to 15
Reverse rotation
Reverse rotation
+2.5V
(+5V)
+2.5V
(+5V)
STF Signal
ON
STF Signal
ON