Mitsubishi Electronics FR-F700-NA ユーザーズマニュアル

ページ / 416
60
4.1.3
Easy operation mode setting (easy setting mode)
Setting of Pr. 79 Operation mode selection according to combination of the start command and speed command can
be easily made.
Operation example Start command: external (STF/STR), frequency command: operate with 
Operation Display 
1. Screen at powering ON
The monitor display appears.
2. Press and for 
0.5s.
3. Turn  
until   
appears. 
(refer to the table below for other settings)
* To use 
 as a potentiometer, refer to page 316
4. Press
 to set.
Flicker ··· Parameter setting complete!!
The monitor display appears after 3s.
REMARKS
 is displayed ... Why?
Pr. 79 is not registered in user group with "1" in Pr. 160 User group read selection.
Parameter write is disabled with "1" set in Pr. 77.
is displayed ... Why?
Setting cannot be changed during operation. Turn the start command (
 or 
, STF or STR) OFF.
If 
 is pressed before pressing 
, the easy setting mode is terminated and the display goes back to the monitor display. If
the easy setting mode is terminated while Pr. 79 = "0 (initial setting)," the operation mode switches between the PU operation mode
and the External operation mode. Check the operation mode. 
Reset can be made with 
.
The priorities of the frequency commands when Pr. 79 = "3" are "Multi-speed operation (RL/RM/RH/REX) > PID control (X14) >
terminal 4 analog input (AU) > digital input from the operation panel".
Flickering
Operation Panel Indication
Operation Method
Start command
Frequency command
*
External
(STF, STR)
Analog
voltage input
External
(STF, STR)
*
Analog
voltage input
Flickering
Flickering
Flickering
Flickering